V4 Plus Individual Type

380-415V-3N~50Hz

The capacity range of outdoor unit is from 20kW to 90kW with two discharge type (side discharge and top discharge). The capacity of side discharge type is from 20kW to 45kW and top discharge type is from 25.2kW to 90kW.

Category:

Description

Introduction

Based on strong R&D strength and years of experience in commercial air conditioning industry, as well as our consistent concern on environment and global warming, Midea proudly introduces the V4 Plus VRF product,which is designed to optimize performance and better match varieties of application requirement.
Especially, the integrated designed V4 Plus Individual Type is focus on provide better air conditioning system solution for the small and middle-sized buildings in the global market.

Specification
HP 7 8 9 14 16
Model MDV- V200W/DRN1 V224W/DRN1 V260W/DRN1 V400W/DRN1 V450W/DRN1
Power supply V/Ph/Hz 380-415/3/50
Cooling Capacity kW 20 22.4 26 40 45
Power input kW 6.1 6.8 7.6 11.9 13.6
EER 3.28 3.29 3.42 3.35 3.32
Heating Capacity kW 22 24.5 28.5 45 50
Power input kW 6.1 5.9 6.8 11.1 12.7
COP 3.61 4.15 4.19 4.05 3.93
Connectable
indoor unit
Total capacity 50~130% of outdoor unit capacity
Max. quantity 10 11 12 14 15
Compressor Type DC inverter
Quantity 1 1 1 2 2
Fan motor Type DC motor +AC motor
Quantity 2 2 2 2 2
Refrigerant Type R410A
Factory charging kg 4.8 6.2 6.2 9 12
Pipe
connections
Liquid pipe mm Ф9.53 Ф9.53 Ф9.53 Ф12.7 Ф12.7
Gas pipe mm Ф19.1 Ф19.1 Ф22.2 Ф22.2 Ф25.4
Air flow rate m3/h 10999 10494 10494 16575 16575
Sound pressure level dB(A) 59 59 60 62 62
Net dimension (W×H×D) mm 1120×1558×528 1360×1650×540 1460×1650×540
Packing size (W×H×D) mm 1270×1720×565 1450×1785×560 1550×1785×560
Net weight kg 137 146.5 147 240 275
Gross weight kg 153 162.5 163 260 290
Operating temperature range °C Cooling: -15~46; Heating: -15~24 Cooling: -5~48; Heating: -15~24

Capacities are based on the following conditions:
Cooling: Indoor temperature 27oC DB/19oC WB; Outdoor temperature 35oC DB/24oC WB.
Heating: Indoor temperature 20oC DB/15oC WB; Outdoor temperature 7oC DB/6oC WB.
Piping length: Interconnecting piping length is 7.5m, level difference is zero.
Sound values are measured in a semi-anechoic room, at a position 1m in front of the unit and 1.3m above the floor.

HP 8 10 12 14
Model MDV- 252W/DRN1-i(B) 280W/DRN1-i(B) 335W/DRN1-i(B) 400W/DRN1-i(B)
Power supply V/Ph/Hz 380-415/3/50
Cooling Capacity kW 25.2 28 33.5 40
Power input kW 5.9 7.2 9.1 12.3
EER 4.29 3.89 3.7 3.25
Heating Capacity kW 27 31.5 37.5 45
Power input kW 6.2 7.6 9 11.2
COP 4.39 4.14 4.17 4.02
Connectable
indoor unit
Total capacity 50~130% of outdoor unit capacity
Max. quantity 13 16 16 16
Compressor Type DC inverter DC inverter+Fixed
Quantity 1 1 2 3
Fan motor Type DC motor
Quantity 1 1 2 2
Max Static Pressure Pa 20 (default)
Pa 40 (customized)
Refrigerant Type R410A
Factory charging kg 10 10 12 15
Pipe
connections
Liquid pipe mm Ф12.7 Ф12.7 Ф15.9 Ф15.9
Gas pipe mm Ф25.4 Ф25.4 Ф31.8 Ф31.8
Air flow rate m3/h 11000 11000 15000 15000
Sound pressure level dB(A) 57 57 58 60
Net dimension (W×H×D) mm 960×1615×765 1250×1615×765
Packing size (W×H×D) mm 1025×1790×830 1305×1790×820
Net weight kg 205 275 325
Gross weight kg 220 295 345
Operating temperature range °C Cooling: -5~48; Heating: -15~24

Notes:
Capacities are based on the following conditions:
Cooling: Indoor temperature 27oC DB/19oC WB; Outdoor temperature 35oC DB/24oC WB.
Heating: Indoor temperature 20oC DB/15oC WB; Outdoor temperature 7oC DB/6oC WB.
Piping length: Interconnecting piping length is 7.5m, level difference is zero.
Connection piping diameter is based on the condition that the total equivalent liquid length is less than 90m. When the total equivalent liquid length is more than 90m, please refer to technical manual to choose the connection piping diameter.
Sound values are measured in a semi-anechoic room, at a position 1m in front of the unit and 1.3m above the floor.

HP 16 20 22 24
Model MDV- 450W/DRN1-i(B) 560W/DRN1-i(C) 615W/DRN1-i(C) 670W/DRN1-i(C)
Power supply V/Ph/Hz 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50
Cooling Capacity kW 45 56 61.5 67
Power input kW 14 17 18.8 20.8
EER 3.21 3.3 3.27 3.22
Heating Capacity kW 50 63 69 75
Power input kW 12.8 16 17.9 19.8
COP 3.91 3.94 3.86 3.79
Connectable
indoor unit
Total capacity 50~130% of outdoor unit capacity
Max. quantity 20 33 36 39
Compressor Type DC inverter +Fixed
Quantity 3 3 3 3
Fan motor Type DC motor DC motor +AC motor
Quantity 2 2 2 2
Max Static Pressure Pa 20 (default)
Pa 40 (customized)
Refrigerant Type R410A
Factory charging kg 15 17 18.5 18.5
Pipe
connections
Liquid pipe mm Ф15.9 Φ19.1 Φ19.1 Φ19.1
Gas pipe mm Ф31.8 Φ31.8 Φ31.8 Φ31.8
Air flow rate m3/h 15000 20000 23000 23000
Sound pressure level dB(A) 60 62 63 63
Net dimension (W×H×D) mm 1250×1615×765 1390×1615×765 1585×1615×765
Packing size (W×H×D) mm 1305×1790×820 1455×1790×830 1650×1810×840
Net weight kg 325 360 385 390
Gross weight kg 345 375 400 405
Operating temperature range °C Cooling: -5~48; Heating: -15~24

Notes:
Capacities are based on the following conditions:
Cooling: Indoor temperature 27oC DB/19oC WB; Outdoor temperature 35oC DB/24oC WB.
Heating: Indoor temperature 20oC DB/15oC WB; Outdoor temperature 7oC DB/6oC WB.
Piping length: Interconnecting piping length is 7.5m, level difference is zero.
Connection piping diameter is based on the condition that the total equivalent liquid length is less than 90m. When the total equivalent liquid length is more than 90m, please refer to technical manual to choose the connection piping diameter.
Sound values are measured in a semi-anechoic room, at a position 1m in front of the unit and 1.3m above the floor.

HP 26 28 30 32
Model MDV- 730W/DRN1-i(C) 785W/DRN1-i(C) 850W/DRN1-i(C) 900W/DRN1-i(C)
Power supply V/Ph/Hz 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50
Cooling Capacity kW 73 78.5 85 90
Power input kW 22.3 24.2 28.3 28.5
EER 3.27 3.24 3 3.16
Heating Capacity kW 81.5 87.5 95 100
Power input kW 20.6 22.4 26 26.5
COP 3.96 3.91 3.65 3.77
Connectable
indoor unit
Total capacity 50~130% of outdoor unit capacity
Max. quantity 43 46 50 53
Compressor Type DC inverter +Fixed
Quantity 3 3 4 5
Fan motor Type AC motor
Quantity 4 4 4 4
Max Static Pressure Pa 20 (default)
Pa 40 (customized)
Refrigerant Type R410A
Factory charging kg 27 27 27 27
Pipe
connections
Liquid pipe mm Φ22.2 Φ22.2 Φ22.2 Φ22.2
Gas pipe mm Φ38.1 Φ38.1 Φ38.1 Φ38.1
Air flow rate m3/h 33100 33100 33100 33100
Sound pressure level dB(A) 64 64 65 65
Net dimension (W×H×D) mm 2540×1615×765
Packing size (W×H×D) mm 2600×1800×825
Net weight kg 555 600
Gross weight kg 590 635
Operating temperature range °C Cooling: -5~48; Heating: -15~24

Notes:
Capacities are based on the following conditions:
Cooling: Indoor temperature 27oC DB/19oC WB; Outdoor temperature 35oC DB/24oC WB.
Heating: Indoor temperature 20oC DB/15oC WB; Outdoor temperature 7oC DB/6oC WB.
Piping length: Interconnecting piping length is 7.5m, level difference is zero.
Connection piping diameter is based on the condition that the total equivalent liquid length is less than 90m. When the total equivalent liquid length is more than 90m, please refer to technical manual to choose the connection piping diameter.
Sound values are measured in a semi-anechoic room, at a position 1m in front of the unit and 1.3m above the floor.

Read more about the product – Here

Features

Wide range of outdoor units
The capacity range of outdoor unit is from 20kW to 90kW with two discharge type (side discharge and top discharge). The capacity of side discharge type is from 20kW to 45kW and top discharge type is from 25.2kW to 90kW.
Wide range of outdoor units

Wide operation range
The V4 Plus Individual series system operates stably at extreme temperatures ranging from -15°C to 48°C.
Wide operation range

High efficiency DC inverter compressor
High efficiency DC inverter twin rotary compressor (available for side discharge type)
High efficiency DC inverter compressor

High efficiency DC inverter compressor
High efficiency DC inverter scroll compressor (available for top discharge type) Powerful magnets provide high torque and efficiency and achieve 70% reduction in volume.
High efficiency DC inverter compressor2

High efficiency DC fan motor
According to the running load and system pressure, the system controls the speed of DC fan to achieve the minimum energy consumption and best performance.
High efficiency DC fan motor

Optimized fan shape and fan grille
Optimized fan blade shape with new air outlet grille enhanced air flow volume which greatly improves fan performance and decreases noise.
Optimized fan shape and fan grille

Integrated design enhance installation efficiency and quality
Compare with combination units, the individual units don’t need complicated piping and wiring in the jobsite. It eliminates the communication wire, power wire, oil balance pipe, and refrigerant distributors between units.
Integrated design enhance installation efficiency and quality

Compact design for effective use of space
Compact size and light weight design minimizes the installation footprint, reduces the installation floor load, and is easier for transportation. For some projects the units can even be transported through the elevator or forklift, reduce access problem at the jobsite.
Compact design for effective use of space

Easy piping connection
The side air discharge type offering four directions to connect pipes and wirings for meet a variety installation request.
Easy piping connection

Easy access
Reserved checking window on electric control box for convenient spot checking and status enquiry.
Compressors locate at near door position which is convenient for checking or replacing the valves or compressor parts.
Easy access

Download

File Name Date File Size Click to download
[1602-2V1511] VRF Catalogue 50Hz 2015-12-17 10.6MB download
V4+I Side Discharge Type TSM 50Hz 2015-6-9 5.17MB download
V4+I Top Discharge Type TSM 50Hz 2015-6-9 5.15MB download