Specification

Model

D252(8)W

D280(10)W

D335(12)W

D400(14)W

D450(16)W

Power Supply

V/Ph/Hz

380-415/3/50

Capacity

Cooling*

RT

7.2

8.0

9.5

11.4

12.8

kW

25.2

28

33.5

40

45

Btu/h

86,000

95,500

114,300

136,500

153,500

kcal/h

21,672

24,080

28,810

34,400

38,700

Cooling**

RT

7

7.4

8.7

10.5

11.7

kW

24.5

25.8

30.8

36.7

41.24

Btu/h

83,940

88,030

105,090

125,220

140,580

kcal/h

21070

22188

26488

31562

35466.4

Heating

RT

7.7

8.9

10.7

12.8

14.2

kW

27

31.5

37.5

45

50

Btu/h

92,100

107,500

128,000

153,500

170,600

kcal/h

23,220

27,090

32,250

38,700

43,000

Power Input

Cooling*

kW

5.79

6.83

8.17

9.64

11.25

Cooling**

kW

7.50

8.70

10.40

12.10

14.40

Heating

kW

5.63

7

8.06

9.57

11.11

EER*

W/W

4.35

4.1

4.1

4.15

4

EER**

W/W

3.27

2.97

2.96

3.03

2.86

COP

W/W

4.8

4.5

4.65

4.7

4.5

Max. Input

kW

15

15

17

24

24

Max. Current

A

28

28

28

42

42

Compressor

Type×Number

Digital×1+Fixed×1

Digital×1+Fixed×1

Digital×1+Fixed×1

Digital×1+Fixed×2

Digital×1+Fixed×2

Oil Type

Digital

POE

Fixed

POE

Oil Charge

Digital(ml)

initial: 1893  refill: 1774

Fixed(ml)

initial: 1656  refill: 1538

initial: 1685  refill: 1567

Fan Motor

Type×Number

DC×1

DC×1

DC×1

DC×1+AC×1

DC×1+AC×1

Output

DC(W)

750

750

750

575

575

AC(W)

670

670

External Static Pressure

Pa

0~20 (default) 20~40 (need to customize)

Air Flow

m3/h

11,700

11,700

11,700

15,600

15,600

CFM

6,887

6,887

6,887

9,183

9,183

Sound Pressure Level

dB(A)

57

57

58

60

61

Refrigerant

Type

R410A

R410A

R410A

R410A

R410A

Charge

kg(Ibs)

9(19.8)

9(19.8)

10(22)

14(30.9)

14(30.9)

Throttle Type

EEV(D32MISZ-1R)

Design Pressure (Hi/Lo)

MPa

4.4/2.6

Pipe
Connection

Liquid Pipe

mm(inch)

12.7(1/2)

12.7(1/2)

15.9(5/8)

15.9(5/8)

15.9(5/8)

Gas Pipe

mm(inch)

25.4(1)

25.4(1)

31.8(1 1/4)

31.8(1 1/4)

31.8(1 1/4)

Dimension (W×H×D)

mm

960×1615×765

960×1615×765

960×1615×765

1250×1615×765

1250×1615×765

inch

37.8×63.6×30.1

37.8×63.6×30.1

37.8×63.6×30.1

49.2×63.6×30.1

49.2×63.6×30.1

Packing (W×H×D)

mm

1025×1790×830

1025×1790×830

1025×1790×830

1305×1790×820

1305×1790×820

inch

40.4×70.5×32.7

40.4×70.5×32.7

40.4×70.5×32.7

51.4×70.5×32.3

51.4×70.5×32.3

Net Weight

kg(Ibs)

240(529)

240(529)

240(529)

335(737)

335(737)

Gross Weight

kg(Ibs)

255(562)

255(562)

255(562)

350(771)

350(771)

Connectable
Indoor Unit

Total Capacity

%

50-130

Max. Quantity

13

16

20

23

26

Ambient Temperature Range

Cooling: -15~54  Heating: -15~24

Notes: Capacities are based on the following conditions:

Cooling*: Indoor temperature 27℃DB/19℃WB; Outdoor temperature 35℃DB/24℃WB

Cooling**: Indoor temperature 29℃DB/19℃WB; Outdoor temperature 46℃DB/24℃WB

Heating: Indoor temperature 20℃DB/15℃WB; Outdoor temperature 7℃DB/6℃WB

Piping length: Interconnecting piping length 7.5m, level difference of zero.

Conversion Formula: RT=kW×0.284; Kcal/h= kW×860; Btu/h= kW×3412; CFM=m3/h×0.588

The model name D252(8)W is simplified for name MDVT-D252(8)W/RN1-B. It is same as other model name.

Read more about the product – Here

Features

Wide range of outdoor units
The outdoor units capacity range from 8HP up to 64HP in 2HP increment. Maximum 64 indoor units with capacity up to 130% of total outdoor units can be connected in one refrigeration system.
Wide range of outdoor units

Long piping length
The solution supports an incredible piping length of 1,000m and level difference of 110m, making it perfect for large projects.
Long piping length

Duty Cycling
In one combination, any outdoor unit can run as the master outdoor unit to equalize the service life of all units.
Duty Cycling

Back-up Function
In a multiple system, when the master unit failed, any single unit can be set as the master unit, then the remaining units can keep on working. This can be set on main board by DIP switch at site.
Back-up Function

High efficiency oil balance and oil return technology
Four stages oil control technology ensure every outdoor’s and compressor’s oil always keep in the safe level, completely avoid being oil shortage.
High efficiency oil balance and oil return technology

High COP/EER values
The D4 PLUS Series with high efficient digital scroll compressor, DC motor and high efficient heat exchanger, achieve the world’s Top Class energy efficiency. The cooling EER up to 4.29 and the heating COP up to 4.6 in the 8HP category.
High COP-EER values

Digital Scroll Compressor
The digital scroll compressor utilizes axial compliant sealing technology to precisely adjust the axial motion range of the stator scroll pan. And there is an additional connecting by-pass between the suction inlet and the pressure bore at the floating sealing point of axial stator.
Digital Scroll Compressor

Wider operation range
No matter in extremely cold winter when outdoor temperature down to -15℃, or in summer when temperature is up to 54℃, the D4+ system will keep stable operation.
Wider operation range

Download

File Name Date File Size Click to download
[1602-4V] T3 D4+ Catalogue 50&60Hz 2015-12-17 9.48MB download
R410A Tropical Digital Scroll D4+ TSM 50Hz 2015-6-9 16.97MB download